White-Rodgers Beige and
White Thermostats for Residential Heating

WHITE-RODGERS®*
We are a distributor for
White-Rodgers
Other Line Voltage Control Thermostats
(To control 120, 208 or 240 Volt electric heaters)
LINE VOLTAGE WALL THERMOSTATS
Electric Heat Thermostats used for Controlling Baseboards, Cable Heat, Glass
Panels, etc.
FEATURES
• 1A66 types are a double-pole disconnect model with “OFF” position which
mechanically breaks both sides of line.
• Classic White or Beige color.
SPECIFICATIONS
Dimensions . . . . . . . . . . . . . . . . . . . . . . . 41/2”H x 23/4”W x
11/4”D
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. listed and
C.S.A. certified
Model Switch Resistive
Number Range Differential Action (Non-Inductive)
1A65-641 40 to 85°F (4 to 29°C) 1 .0°F Open on Rise 22.0A, 120 VAC (2500W)
1A65W-641 ➀ 22.0A, 240 VAC (5000W)
1 8.0A, 277 VAC (5000W)
1A66-641 40 to 85°F (4 to 29°C) 1 .0°F Open on Rise 22.0A, 240 VAC (5000W)
1A66W-641 ➀ 1 8.0A, 277 VAC (5000W)
Single Pole
Thermostat


- For Line Voltage
- 40 to 85°F
- 22 amp 120/240V
- 18 amp 277V
- Single Pole Single Throw
- Differential 1°F
- Non-Inductive use (heaters without motors/fans)
The WR-65 Electric Heat Thermostat is designed for use on
electric heating installations such as cable heat, baseboards, radiant, etc. Its narrow operating differential and the ability of its
fully exposed knob to sense both radiant heat and room air temperature make this
control ideal for use on such installations. The
knob may not be turned to off
position to obtain temporary shutdown of the heating equipment for short
periods of time such as on weekends, vacations, etc.
Double Pole
Thermostat


- For Line Voltage
- Double Line Disconnect
- 40 to 85°F
- 22
amp 240V
- 18 amp 277V
- Double Pole Single Throw
- Differential 1°F
- Non-Inductive use (heaters without motors/fans)
The WR-66 Electric Heat Thermostat is designed for use on
electric heating installations such as cable heat, baseboards, radiant, etc. Its narrow operating differential and the ability of its
fully exposed knob to sense both radiant heat and room air temperature make this
control ideal for use on such installations. It is intended for use on 240 or
277 volts where local codes require that a double line disconnect thermostat be
used. The knob may be turned past 40°F to the "OFF" position to obtain temporary
shutdown of the heating equipment for short periods of time such as on weekends,
vacations, etc. (will break both sides of line.)
|
Secure
Online Ordering
*Delivery time: typically ships in 1 working day or less plus allow additional time for your selected UPS or FedEx shipping method. Your shipping cost will be displayed in your shopping cart. |
|
Item ID |
Catalog# |
Description |
Price |
Click "Select" below to see our actual real-time quantity in stock |
|
WR10001 |
1A65-641 |
Beige WR-65 SPST Thermostat, 40°F to 85°F, 120/240/277V, Single Pole, wall mount |
$26.35 |
 |
|
WR10002 |
1A66-641 |
Beige WR-66 DPST Thermostat, 40°F to 85°F, 240/277V, Double Pole (D.P.S.T., Includes off
position), wall mount |
$26.35 |
 |
|
WR10037 |
1A65W-641 |
White WR-65W SPST Thermostat, 40°F to 85°F, 120/240/277V, Single Pole, wall mount |
$26.35 |
 |
|
WR10038 |
1A66W-641 |
White WR-66W DPST Thermostat, 40°F to 85°F, 240/277V, Double Pole (D.P.S.T., Includes off
position), wall mount |
$26.35 |
 |
|
*This delivery time is for normal conditions and
is subject to factory availability. |
*White-Rodgers and the WR logo are trademarks
of White-Rodgers, Inc.
|