Qmark Type CRA Wall Heaters
(Residential Fan Forced Zonal Heaters)


We are an authorized distributor for Qmark®,
a division of Marley Engineered Products.
Links to other types of Wall Heaters:
Qmark Commercial Fan
Forced Wall Heaters (Type CWH1000)
Qmark Commercial Fan
Forced Wall Heaters (Type CWH3000)
Qmark Architectural Heavy Duty Fan
Forced Wall Heaters (Type AWH)
Qmark Commercial Fan Forced Wall Heaters
(Type EFQ)
Complete unit: Back box, heater assembly,
grille, and factory installed DP thermostat (Range 40 - 85°F). Optional Surface
Mounting Frame is also available.
-
Suitable for use in almost any room.
-
Fast-response coil element assures quick heat and low
maintenance.
-
Three piece construction offers ease of installation
-
Attractive European styled grille with rounded corners
complements any room decor.
-
Dual protection: Thermal cutout with indicator light
and one time thermal fuse.
-
Sienna White baked enamel finish.
-
500 - 1000 Watt units are approved for ceiling mounting.
-
Wattage levels should be determined by heat loss calculations.
-
Patented Clip-n-Fit
Feature
|
-
Grill: 12-1/4"H x 10-1/2"W x 3/4"D
-
Backbox: 11-1/8"H x 9-3/8"W x 3-3/4"D
-
Use single heaters in
smaller rooms such as bedrooms and bathrooms.
-
Use multiple heaters (controlled
by a single thermostat) in larger rooms such as living rooms and family rooms.
-

|

 |

Mounting Limitations
Do not install back box closer than 4.5 inches from floor, adjacent walls
and 12 inches from ceiling. Units 1000W or less can be ceiling mounted. Do not
install heater behind towel rack, behind door, in floor, in closet, or where
airflow may be obstructed. To insure proper operation, maintain 5 feet minimum
clearance to furniture or other objects placed directly in front of the heater. Note:
For installations over 7,500 feet above sea level Qmark recommends using models
under 1500 watts. |
Selecting Heaters:
Use the calculator below for selecting the quantity and wattage of wall heaters you will need in
a given area, when using the heaters as a primary heat
source (no other heaters present.) Supplementing existing heaters such as a
forced air furnace system requires less wattage. A general rule of thumb for primary heating is to use 10 Watts / Square Foot
of heat. Example: a 10'x10' room is 100 square feet: (100 x 10 W/Ft2
= 1000 Watts.)
Keep in mind that this is for an insulated building or room insulated to "electric heating" standards and is an
estimation based on average conditions.
|
Secure
Online Ordering
*Delivery time: typically ships in 1 working day or less plus the time of
your selected UPS shipping method. Items not
currently in stock will show "call for availability" when added to your shopping
cart, and will ship in 7-10 workdays. Your shipping cost will be displayed in your shopping cart. |
|
Item ID |
Catalog# |
Volts |
Watts |
Amps |
BTU/HR. |
Price |
Click "Select" below to see the actual quantity in stock |
|
Complete units with built-in double pole
thermostat, back box, grill and heater assembly: |
|
QMARK685360017396 |
CRA1512-T2 |
120 |
1500/1125/750/375 |
12.5/9.4/6.3/3.1 |
5118/3838/2560/1280 |
$99.44 |
 |
|
QMARK685360017433 |
CRA2024-T2 |
240
208 |
2000/1500/1000/500
1500/1125/750/375 |
8.3/6.3/4.2/2.1
12.5/9.4/6.3/3.1 |
6824/5118/3412/1706
5118/3838/2560/1280 |
$99.44 |
 |
|
QMARK685360017495 |
CRA2224-T2 |
240
208 |
2250/1688/1125/863
1688/1266/844/422 |
9.4/7.0/4.7/2.4
8.1/6.1/4.1/2.0 |
7677/5760/3838/1920
5760/4320/2880/1440 |
$99.44 |
 |
|
Inner frame units with grill and heater
assembly only, order back box separately: |
|
QMARK685360017389 |
CRA1512-IF |
120 |
1500/1125/750/375 |
12.5/9.4/6.3/3.1 |
5118/3838/2560/1280 |
$86.68 |
 |
|
QMARK685360017440 |
CRA2028-IF |
208 |
2000/1500/1000/500 |
9.6/7.2/4.8/2.4 |
6824/5118/3412/1706 |
$86.68 |
 |
|
QMARK685360017426 |
CRA2024-IF |
240
208 |
2000/1500/1000/500
1500/1125/750/375 |
8.3/6.3/4.2/2.1
12.5/9.4/6.3/3.1 |
6824/5118/3412/1706
5118/3838/2560/1280 |
$86.68 |
 |
|
QMARK685360017488 |
CRA2224-IF |
240
208 |
2250/1688/1125/863
1688/1266/844/422 |
9.4/7.0/4.7/2.4
8.1/6.1/4.1/2.0 |
7677/5760/3838/1920
5760/4320/2880/1440 |
$86.68 |
 |
|
Accessories: |
|
QMARK685360017235 |
CRASM |
Optional Surface Mounting Frame |
$26.13 |
 |
|
QMARK685360017198 |
CRABB |
Back Box Only (Used with *-IF suffix
models) |
$12.70 |
 |
|
QMARK685360017204 |
CRABB6 |
Back
Multi pack 6 pieces (Used with *-IF suffix models) |
$73.97 |
 |
|
QMARK685360017266 |
CRATDP |
Double Pole Thermostat Kit
(Range: 40 - 85°) |
$22.41 |
 |
|
QMARK685360113074 |
CRA2AFAKIT
|
Retro Kit for A Series Back Box |
$12.48 |
 |
|
Wall
Mount Thermostats: (Optional) |
|
WR10001 |
WR-65 |
1A65-641 WR-65 SPST Thermostat, 40°F to 85°F, 22 amp 120/240V, 18 amp 277V, Single Pole, wall mount |
$26.35 |
 |
|
WR10002 |
WR-66 |
1A66-641 WR-66 DPST Thermostat, 40°F to 85°F, 22 amp 240V, 18 amp 277V, Double Pole (D.P.S.T., Includes
off position), wall mount |
$26.35 |
 |
|
AUBE10003 |
TH106 |
Aube Tech. 120/240V, S.P.S.T., Programmable Line Voltage
Thermostat |
$63.67 |
 |
|
AUBE10010 |
TH115-A-240D |
Aube Tech. Double Pole, 240V Programmable Line Voltage Thermostat,
3600W @ 240 V 15 A resistive 60 Hz 4 wires /
D.P.S.T. |
$66.17 |
 |
|
QMARK98319841025 |
TC1 |
Qmark Clear Plastic Universal Lockable
Thermostat Guard. Dimensions: 7"L x 4.28"H x 2.74"D. |
$52.20 |
 |
|
*This delivery time is for normal conditions and
is subject to factory availability. |
Qmark® is a registered